BARREL 2T X-ray Spectrometer (SSPC) Bremsstrahlung X-ray Spectrum Slow Time...
SSPC: 256 channels of slow time resolution, 32 s, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. The nominal energy range covered by the 256 channels ranges from... -
BARREL 2T Rate Counter (RCNT) NaI Scintillator Diagnostics, Level 2, 4 s Data
This data product consists of measurements from rate counters. The rate count data are diagnostic fields, have uncalibrated energy ranges, and wrap near or above 16384 counts/s.... -
BARREL 2T X-ray Spectrometer (MSPC) Bremsstrahlung X-ray Spectrum Medium...
MSPC: 48 channels of medium time resolution, 4 s, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. The nominal energy range covered by the 48 channels ranges from... -
BARREL 2T Tri-axial Fluxgate Magnetometer (MAGN) Magnetic Field Data, no...
Three axis DC magnetometer data with nominal conversions applied. Data are neither gain corrected nor despun. The BARREL Mission was a multiple-balloon investigation designed to... -
BARREL 2T Data Processing Unit (HKPG) Analog Housekeeping Voltage,...
Housekeeping voltage, temperature, current, and payload status values returned every 40 s. NOTE: The analog sensor data in these records are based on the nominal BARREL... -
BARREL 2T X-ray Spectrometer (FSPC) Bremsstrahlung X-ray Spectrum Fast Time...
FSPC: Six channels of fast time resolution, 50 ms, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. Each channel is separated in its own variable: FSPC1a, FSPC1b,... -
BARREL 2T Ephemeris (EPHM) Geographic and Magnetic Coordinates, Level 2, 4 s Data
Geographic and Magnetic Coordinates: The ephemeris data products, which include the balloon epoch time, latitude, longitude, and altitude, are each returned from the payload... -
BARREL 2Q X-ray Spectrometer (SSPC) Bremsstrahlung X-ray Spectrum Slow Time...
SSPC: 256 channels of slow time resolution, 32 s, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. The nominal energy range covered by the 256 channels ranges from... -
BARREL 2Q Rate Counter (RCNT) NaI Scintillator Diagnostics, Level 2, 4 s Data
This data product consists of measurements from rate counters. The rate count data are diagnostic fields, have uncalibrated energy ranges, and wrap near or above 16384 counts/s.... -
BARREL 2Q X-ray Spectrometer (MSPC) Bremsstrahlung X-ray Spectrum Medium...
MSPC: 48 channels of medium time resolution, 4 s, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. The nominal energy range covered by the 48 channels ranges from... -
BARREL 2Q Tri-axial Fluxgate Magnetometer (MAGN) Magnetic Field Data, no...
Three axis DC magnetometer data with nominal conversions applied. Data are neither gain corrected nor despun. The BARREL Mission was a multiple-balloon investigation designed to... -
BARREL 2Q Data Processing Unit (HKPG) Analog Housekeeping Voltage,...
Housekeeping voltage, temperature, current, and payload status values returned every 40 s. NOTE: The analog sensor data in these records are based on the nominal BARREL... -
BARREL 2Q X-ray Spectrometer (FSPC) Bremsstrahlung X-ray Spectrum Fast Time...
FSPC: Six channels of fast time resolution, 50 ms, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. Each channel is separated in its own variable: FSPC1a, FSPC1b,... -
BARREL 2Q Ephemeris (EPHM) Geographic and Magnetic Coordinates, Level 2, 4 s Data
Geographic and Magnetic Coordinates: The ephemeris data products, which include the balloon epoch time, latitude, longitude, and altitude, are each returned from the payload... -
BARREL 2P X-ray Spectrometer (SSPC) Bremsstrahlung X-ray Spectrum Slow Time...
SSPC: 256 channels of slow time resolution, 32 s, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. The nominal energy range covered by the 256 channels ranges from... -
BARREL 2P Rate Counter (RCNT) NaI Scintillator Diagnostics, Level 2, 4 s Data
This data product consists of measurements from rate counters. The rate count data are diagnostic fields, have uncalibrated energy ranges, and wrap near or above 16384 counts/s.... -
BARREL 2P X-ray Spectrometer (MSPC) Bremsstrahlung X-ray Spectrum Medium...
MSPC: 48 channels of medium time resolution, 4 s, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. The nominal energy range covered by the 48 channels ranges from... -
BARREL 2P Tri-axial Fluxgate Magnetometer (MAGN) Magnetic Field Data, no...
Three axis DC magnetometer data with nominal conversions applied. Data are neither gain corrected nor despun. The BARREL Mission was a multiple-balloon investigation designed to... -
BARREL 2P Data Processing Unit (HKPG) Analog Housekeeping Voltage,...
Housekeeping voltage, temperature, current, and payload status values returned every 40 s. NOTE: The analog sensor data in these records are based on the nominal BARREL... -
BARREL 2P X-ray Spectrometer (FSPC) Bremsstrahlung X-ray Spectrum Fast Time...
FSPC: Six channels of fast time resolution, 50 ms, Bremsstrahlung X-ray spectra detected with a NaI Scintillator. Each channel is separated in its own variable: FSPC1a, FSPC1b,...