4709 Results
filtered by...
Filter
4709 Results
filtered by
Tags > atmosphere
Clear All
External Link
TL2H2OLN_7 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Water Vapor Lite Nadir Version 7 data product. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits.
A nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consisted of four files, where each file was composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix. A Global Survey consisted of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals were performed. Each observation was the input for retrievals of species volume mixing ratios (VMRs), temperature profiles, surface temperature and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density, and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object was bounded by the number of observations in a global survey and a predefined set of pressure levels representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging is employed. Also, missing or bad retrievals were not reported.
The organization of data within the Swath object was based on a superset of the Upper Atmosphere Research Satellite (UARS) pressure levels that was used to report concentrations of trace atmospheric gases. The reporting grid was the same pressure grid used for modeling. There were 67 reporting levels from 1211.53 hPa, which allowed for very high surface pressure conditions, to 0.1 hPa, about 65 km. In addition, the products reported values directly at the surface when possible or at the observed cloud top level. Thus in the Standard Product files each observation could potentially contain estimates for the concentration of a particular molecule at 67 different pressure levels within the atmosphere. However, for most retrieved profiles, the highest pressure levels were not observed due to a surface at lower pressure or cloud obscuration. For pressure levels corresponding to altitudes below the cloud top or surface, where measurements were not possible, a fill value was applied.
To minimize the duplication of information between the individual species standard products, data fields common to each species (such as spacecraft coordinates, emissivity, and other data fields) have been collected into a separate standard product, termed the TES L2 Ancillary Data product (ESDT short name: TL2ANC). Users of this product should also obtain the Ancillary Data product.
Created
October 14 2024
Views
0
External Link
TL2SUP_7 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Supplemental Profiles Version 7 data product. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. The satellite flew at an altitude of 705 km in an orbit that took it near Earth's North and South Poles. After each orbit, the spacecraft advanced 22° westward. After 233 orbits (16 days) it was then back to its starting point. This product contains input data to the TES radiance forward model. These were profiles generated from climatology databases to be used in the forward model calculation but are not retrieved parameters. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updates the atmospheric parameters.
Level 2 data contains retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits, over which 3,200 retrievals were performed.
Created
October 14 2024
Views
0
External Link
TL2SUP_8 is the the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Supplemental Profiles Version 8 data product. It contains input data to the TES radiance forward model. These were profiles generated from climatology databases to be used in the forward model calculation but are not retrieved parameters. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updates the atmospheric parameters. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines.
Nadir observations, which point directly to the surface of the Earth, are different from limb observations, which are pointed at various off-nadir angles into the atmosphere. Nadir and limb observations were added to separate L2 files, and a single ancillary file was composed of data that are common to both nadir and limb files. A Nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix.
A Global Survey consisted of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals were performed. Each observation was the input for retrievals of species Volume Mixing Ratios (VMRs), temperature profiles, surface temperature, and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density, and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object was bounded by the number of observations in a global survey and a predefined set of pressure levels, representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging was employed. Also, missing or bad retrievals were not reported. Further, observations were occasionally scheduled on non-global survey days. In general they were measurements made for validation purposes or with highly focused science objectives. Those non-global survey measurements were referred to as “special observations.”
A Limb sequence within the TES Global Survey was three high-resolution scans over the same limb locations. The Limb standard product consists of four files, where each file is composed of the Global Survey Limb observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Limb observations used a repeating sequence of filter wheel positions. Special Observations could only be scheduled during the 9 or 10 orbit gaps in the Global Surveys, and were conducted in any o
Created
October 14 2024
Views
0
TL2SUPS_8 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Supplemental Profiles Special Observation Version 8 data product. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits.
Nadir and limb observations were added to separate L2 files, and a single ancillary file was composed of data that are common to both nadir and limb files. A Nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix.
A Global Survey consisted of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals were performed. Each observation was the input for retrievals of species Volume Mixing Ratios (VMRs), temperature profiles, surface temperature, and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density, and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object was bounded by the number of observations in a global survey and a predefined set of pressure levels representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging was employed. Also, missing or bad retrievals were not reported. Further, observations were occasionally scheduled on non-global survey days. In general they were measurements made for validation purposes or with highly focused science objectives. Those non-global survey measurements were referred to as “special observations”
The organization of data within the Swath object was based on a superset of the Upper Atmosphere Research Satellite (UARS) pressure levels used to report concentrations of trace atmospheric gases. The reporting grid was the same pressure grid used for modeling. There were 67 reporting levels from 1211.53 hPa, which allowed for very high surface pressure conditions, to 0.1 hPa, about 65 km. In addition, the products reported values directly at the surface when possible or at the observed cloud top level. Thus in the Standard Product files, each observation could potentially contain estimates for the concentration of a particular molecule at 67 different pressure levels within the atmosphere. However, for most retrieved profiles, the highest pressure levels were not observed due to a surface at lower pressure or cloud obscuration. For pressure levels corresponding to altitudes below the cloud top or surface, where measurements were not possible, a fill value was applied.
To minimize the duplication of information between the individual species standard products, data fields common to each species (such as spacecraft
Created
October 14 2024
Views
0
TL2SUPS_7 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Supplemental Profiles Special Observation Version 7 data product. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits.
Nadir and limb observations were added to separate L2 files, and a single ancillary file was composed of data that are common to both nadir and limb files. A Nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix.
A Global Survey consisted of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals were performed. Each observation was the input for retrievals of species Volume Mixing Ratios (VMRs), temperature profiles, surface temperature, and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density, and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object was bounded by the number of observations in a global survey and a predefined set of pressure levels representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging was employed. Also, missing or bad retrievals were not reported. Further, observations were occasionally scheduled on non-global survey days. In general they were measurements made for validation purposes or with highly focused science objectives. Those non-global survey measurements were referred to as “special observations”
The organization of data within the Swath object was based on a superset of the Upper Atmosphere Research Satellite (UARS) pressure levels used to report concentrations of trace atmospheric gases. The reporting grid was the same pressure grid used for modeling. There were 67 reporting levels from 1211.53 hPa, which allowed for very high surface pressure conditions, to 0.1 hPa, about 65 km. In addition, the products reported values directly at the surface when possible or at the observed cloud top level. Thus in the Standard Product files, each observation could potentially contain estimates for the concentration of a particular molecule at 67 different pressure levels within the atmosphere. However, for most retrieved profiles, the highest pressure levels were not observed due to a surface at lower pressure or cloud obscuration. For pressure levels corresponding to altitudes below the cloud top or surface, where measurements were not possible, a fill value was applied.
To minimize the duplication of information between the individual species standard products, data fields common to each species (such as spacecraft
Created
October 14 2024
Views
0
External Link
TL2SUM_8 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Summary Profiles Version 8 data product. It contains atmospheric vertical profile estimates, along with retrieved surface temperature, cloud effective optical depth, column estimates, quality flags, and priori constraint vectors.TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines.
Nadir observations, which point directly to the surface of the Earth, are different from limb observations, which are pointed at various off-nadir angles into the atmosphere. Nadir and limb observations were added to separate L2 files, and a single ancillary file was composed of data that are common to both nadir and limb files. A Nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix.
A Global Survey consisted of observations along 16 consecutive orbits at the start of a two day cycle, over which 4,608 retrievals were performed. Each observation was the input for retrievals of species Volume Mixing Ratios (VMRs), temperature profiles, surface temperature, and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density, and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object was bounded by the number of observations in a global survey and a predefined set of pressure levels, representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging was employed. Also, missing or bad retrievals were not reported. Further, observations were occasionally scheduled on non-global survey days. In general they were measurements made for validation purposes or with highly focused science objectives. Those non-global survey measurements were referred to as “special observations.”
A Limb sequence within the TES Global Survey was three high-resolution scans over the same limb locations. The Limb standard product consists of four files, where each file is composed of the Global Survey Limb observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Limb observations used a repeating sequence of filter wheel positions. Special Observations could only be scheduled during the 9 or 10 orbit gaps in the Global Surveys, and were conducted in any of three basic modes: stare, transect, step-and-stare. The mode used depended on the science requirement. Each limb observation Limb 1, Limb 2 and Limb 3,
Created
October 14 2024
Views
0
External Link
TL2SUM_7 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Summary Profiles Version 7 data product. It contains atmospheric vertical profile estimates, along with retrieved surface temperature, cloud effective optical depth, column estimates, quality flags, and priori constraint vectors.TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines.
Nadir observations, which point directly to the surface of the Earth, are different from limb observations, which are pointed at various off-nadir angles into the atmosphere. Nadir and limb observations were added to separate L2 files, and a single ancillary file was composed of data that are common to both nadir and limb files. A Nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix.
A Global Survey consisted of observations along 16 consecutive orbits at the start of a two day cycle, over which 4,608 retrievals were performed. Each observation was the input for retrievals of species Volume Mixing Ratios (VMRs), temperature profiles, surface temperature, and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density, and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object was bounded by the number of observations in a global survey and a predefined set of pressure levels, representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging was employed. Also, missing or bad retrievals were not reported. Further, observations were occasionally scheduled on non-global survey days. In general they were measurements made for validation purposes or with highly focused science objectives. Those non-global survey measurements were referred to as “special observations.”
A Limb sequence within the TES Global Survey was three high-resolution scans over the same limb locations. The Limb standard product consists of four files, where each file is composed of the Global Survey Limb observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Limb observations used a repeating sequence of filter wheel positions. Special Observations could only be scheduled during the 9 or 10 orbit gaps in the Global Surveys, and were conducted in any of three basic modes: stare, transect, step-and-stare. The mode used depended on the science requirement. Each limb observation Limb 1, Limb 2 and Limb 3,
Created
October 14 2024
Views
1
External Link
TL2SUMS_8 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Atmospheric Temperatures Limb Version 8 data product. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. TES Level 2 data contains retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) were also provided. L2 modeled spectra were evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compared observed spectra to the modeled spectra and iteratively updated the atmospheric parameters. L2 standard product files included information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consisted of a maximum of 16 consecutive orbits, over which 3,200 retrievals were performed.
A nadir sequence within the TES Global Survey was a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations only used a single set of filter mix. A Global Survey consists of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals were performed. Each observation was the input for retrievals of species volume mixing ratios (VMRs), temperature profiles, surface temperature and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density and other diagnostic quantities. Each TES Level 2 standard product reported information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object wa bounded by the number of observations in a global survey and a predefined set of pressure levels representing slices through the atmosphere. Each standard product could have had a variable number of observations depending upon the Global Survey configuration and whether averaging is employed. Also, missing or bad retrievals were not reported.
The organization of data within the Swath object was based on a superset of the Upper Atmosphere Research Satellite (UARS) pressure levels that was used to report concentrations of trace atmospheric gases. The reporting grid was the same pressure grid used for modeling. There were 67 reporting levels from 1211.53 hPa, which allowed for very high surface pressure conditions, to 0.1 hPa, about 65 km. In addition, the products reported values directly at the surface when possible or at the observed cloud top level. Thus in the Standard Product files each observation could potentially contain estimates for the concentration of a particular molecule at 67 different pressure levels within the atmosphere. However, for most retrieved profiles, the highest pressure levels were not observed due to a surface at lower pressure or cloud obscuration. For pressure levels corresponding to altitudes below the cloud top or surface, where measurements were not possible, a fill value was applied.
To minimize the duplication of information between the individual species standard products, data fields common to each species (such as spacecraft coordinates, emissivity, and other data fields) have been collected into a separate standard product, termed the TES L2 Ancillary Data product (ESDT short name: TL2ANC). Users of this product should also obtain the Ancillary Data product.
Created
October 14 2024
Views
1
External Link
TL2SUMS_7 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Atmospheric Temperatures Limb Version 7 data product. TES was an instrument aboard NASA's Aura satellite and was launched from California on July 15, 2004. Data collection for TES is complete. The satellite flew at an altitude of 705 km in an orbit that took it near Earth's North and South Poles. Each orbit, the spacecraft advanced 22° westward and, after 233 orbits (16 days) it was back to its starting point. This product contains atmospheric vertical profile estimates, along with retrieved surface temperature, cloud effective optical depth, column estimates, quality flags, and a priori constraint vectors.
Created
October 14 2024
Views
1
External Link
TL2RHLN_7 is the Tropospheric Emission Spectrometer (TES)/Aura Level 2 Atmospheric Temperatures Limb Version 7 data product. It contains atmospheric vertical profile estimates and associated errors including the mapping matrix to relate the reduced-size retrieval vectors, covariances, and averaging kernels back to the TES forward model pressure grid. TES Level 2 data contain retrieved species (or temperature) profiles at the observation targets and the estimated errors. The geolocation, quality, and other data (e.g., surface characteristics for nadir observations) are also provided. L2 modeled spectra are evaluated using radiative transfer modeling algorithms. The process, referred to as retrieval, compares observed spectra to the modeled spectra and iteratively updates the atmospheric parameters. L2 standard product files include information for one molecular species (or temperature) for an entire global survey or special observation run. A global survey consists of a maximum of 16 consecutive orbits.
A nadir sequence within the TES Global Survey is a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations currently only use a single set of filter mix. A Global Survey consists of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals are performed. Each observation is the input for retrievals of species Volume Mixing Ratios (VMR), temperature profiles, surface temperature and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density and other diagnostic quantities. Each TES Level 2 standard product reports information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object is bounded by the number of observations in a global survey and a predefined set of pressure levels representing slices through the atmosphere. Each standard product can have a variable number of observations depending upon the Global Survey configuration and whether averaging is employed. Also, missing or bad retrievals are not reported.
The organization of data within the Swath object is based on a superset of the UARS pressure levels used to report concentrations of trace atmospheric gases. The reporting grid is the same pressure grid used for modeling. There are 67 reporting levels from 1211.53 hPa, which allows for very high surface pressure conditions, to 0.1 hPa, about 65 km. In addition, the products will report values directly at the surface when possible or at the observed cloud top level. Thus, in the Standard Product files each observation can potentially contain estimates for the concentration of a particular molecule at 67 different pressure levels within the atmosphere. However, for most retrieved profiles, the highest pressure levels are not observed due to a surface at lower pressure or cloud obscuration. For pressure levels corresponding to altitudes below the cloud top or surface, where measurements were not possible, a fill value will be applied.
To minimize the duplication of information between the individual species standard products, data fields common to each species (such as spacecraft coordinates, emissivity, and other data fields) have been collected into a separate standard product, termed the TES L2 Ancillary Data product (ESDT short name: TL2ANC). Users of this product should also obtain the Ancillary Data product.
A nadir sequence within the TES Global Survey is a fixed number of observations within an orbit for a Global Survey. Prior to April 24, 2005, it consisted of two low resolution scans over the same ground locations. After April 24, 2005, Global Survey data consisted of three low resolution scans. The Nadir standard product consists of four files, where each file is composed of the Global Survey Nadir observations from one of four focal planes for a single orbit, i.e. 72 orbit sequences. The Global Survey Nadir observations currently only use a single set of filter mix. A Global Survey consists of observations along 16 consecutive orbits at the start of a two day cycle, over which 3,200 retrievals are performed. Each observation is the input for retrievals of species Volume Mixing Ratios (VMR), temperature profiles, surface temperature and other data parameters with associated pressure levels, precision, total error, vertical resolution, total column density and other diagnostic quantities. Each TES Level 2 standard product reports information in a swath format conforming to the HDF-EOS Aura File Format Guidelines. Each Swath object is bounded by the number of observations in a global survey and a predefined set of pressure levels representing slices through the atmosphere. Each standard product can have a variable number of observations depending upon the Global Survey configuration and whether averaging is employed. Also, missing or bad retrievals are not reported.
The organization of data within the Swath object is based on a superset of the UARS pressure levels used to report concentrations of trace atmospheric gases. The reporting grid is the same pressure grid used for modeling. There are 67 reporting levels from 1211.53 hPa, which allows for very high surface pressure conditions, to 0.1 hPa, about 65 km. In addition, the products will report values directly at the surface when possible or at the observed cloud top level. Thus, in the Standard Product files each observation can potentially contain estimates for the concentration of a particular molecule at 67 different pressure levels within the atmosphere. However, for most retrieved profiles, the highest pressure levels are not observed due to a surface at lower pressure or cloud obscuration. For pressure levels corresponding to altitudes below the cloud top or surface, where measurements were not possible, a fill value will be applied.
To minimize the duplication of information between the individual species standard products, data fields common to each species (such as spacecraft coordinates, emissivity, and other data fields) have been collected into a separate standard product, termed the TES L2 Ancillary Data product (ESDT short name: TL2ANC). Users of this product should also obtain the Ancillary Data product.
Created
October 14 2024
Views
0